摘要
Real-time diagnostics of ceramic powder injection molding with a micromolding machine was performed using ultrasound. Miniature ultrasonic sensors were integrated onto the mold insert. Melt front, solidification and part detachment of the feedstock inside the mold cavity were observed. The assistance of ultrasonic velocity in feedstock inside the mold cavity, the ultrasonic contact time during which the part and mold are in contact and holding pressure may minimize part dimension variation.
| 原文 | English |
|---|---|
| 頁面 | 2531-2535 |
| 頁數 | 5 |
| 出版狀態 | Published - 2006 |
| 事件 | Society of Plastics Engineers Annual Technical Conference 2006, ANTEC 2006 - Charlotte, NC, United States 持續時間: 7 5月 2006 → 11 5月 2006 |
Conference
| Conference | Society of Plastics Engineers Annual Technical Conference 2006, ANTEC 2006 |
|---|---|
| 國家/地區 | United States |
| 城市 | Charlotte, NC |
| 期間 | 7/05/06 → 11/05/06 |
指紋
深入研究「Real-time diagnosis for micro powder injection molding using ultrasound」主題。共同形成了獨特的指紋。引用此
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver