Experimental study on transient supercooling of two-stage thermoelectric cooler

  • Wen Ken Li
  • , Jhih Hao Chang
  • , Mohammad Amani
  • , Tien Fu Yang
  • , Wei Mon Yan

研究成果: 期刊貢獻文章同行評審

22 引文 斯高帕斯(Scopus)

摘要

In this work, an experimental study was conducted to evaluate the cooling performance of two-stage thermoelectric coolers (TECs) under current pulse operation so as to achieve a larger temperature drop. Measured data disclosed that the steady electric current varied from 0.1 to 4.1 A and the optimal current was found to be Iopt = 2 A. The implementation of transient supercooling was found to reduce the minimum temperature from 236.65 to 232.90 K, corresponding the temperature drop of 3.75 K. The results further indicated that the increment of pulse current leads to the reduction of the Tc,min. However, for τ = 5 s, further increment of the pulse current from 4 A to 4.5 A did not lead to the lower Tc,min, which can be attributed to the large magnitude of the current so that the heat sink cannot remove much heat and it would be fed back to the cold side. Thus, the least Tc,min was achieved for 4 A. Regarding the variation of pulse width, it was obtained that Tc,min is decreased tending to a particular value. Accordingly, the least Tc,min of 232.8 K was attained by applying a pulse current with τ = 6 s.

原文English
文章編號100509
期刊Case Studies in Thermal Engineering
14
DOIs
出版狀態Published - 9月 2019

文獻附註

Publisher Copyright:
© 2019 The Authors.

指紋

深入研究「Experimental study on transient supercooling of two-stage thermoelectric cooler」主題。共同形成了獨特的指紋。

引用此