Real time diagnostics of gas/water assisted injection moulding using integrated ultrasonic sensors

  • L. Mulvaney-Johnson
  • , C. C. Cheng
  • , Y. Ono
  • , E. C. Brown
  • , C. K. Jen
  • , P. D. Coates

Research output: Contribution to journalArticlepeer-review

14 Scopus citations

Abstract

An ultrasound sensor system has been applied to the mould of both the water and gas assisted injection moulding processes. The mould has a cavity wall mounted pressure sensor and instrumentation to monitor the injection moulding machine. Two ultrasound sensors are used to monitor the arrival of the fluid (gas or water) bubble tip through the detection of reflected ultrasound energy from the fluid polymer boundary and the fluid bubble tip velocity through the polymer melt is estimated. The polymer contact with the cavity wall is observed through the reflected ultrasound energy from that boundary. A theoretically based estimation of the residual wall thickness is made using the ultrasound reflection from the fluid (gas or water) polymer boundary while the samples are still inside the mould and a good correlation with a physical measurement is observed.

Original languageEnglish
Pages (from-to)111-121
Number of pages11
JournalPlastics, Rubber and Composites
Volume36
Issue number3
DOIs
StatePublished - 2007

Keywords

  • Gas assisted injection moulding
  • Process management
  • Ultrasound
  • Water assisted injection moulding

Fingerprint

Dive into the research topics of 'Real time diagnostics of gas/water assisted injection moulding using integrated ultrasonic sensors'. Together they form a unique fingerprint.