Abstract
Hypertension related diseases have highly threatened people's health around the globe. What is even worse is that not only the number of hypertension patients has grown dramatically, their ages of onset have also become younger. Blood pressure monitoring is important for hypertension patients. However the traditional blood pressure measurement is inconvenient which results in less people with habits to measure blood pressure. To improve people's incentive of measuring blood pressure, in this study we have developed a wristband prototype for measuring blood pressure. With our wristband prototype, it is easy for users to establish habits of blood pressure measurement and tracking, and subsequently detect hypertension in the early stage. Our wristband prototypes of wearable sphygmomanometer have been utilized to measure 120 subjects' blood pressures. This wristband prototype can simultaneously measure signals of Photoplethysmogram (PPG) and Electrocardiography (ECG), and then compute the interval of the peak time of these two signals as pulse transit time (PTT). Since PTT has been verified to be highly correlated to blood pressure in numerous researches, PTT is suitable for blood pressure estimation. However, since blood vessels in human body are very complicated and they are highly correlated with blood pressure, we have taken some parameters such as the heart rate (HR) and the subject's physiological differences (e.g., height, weight, age and gender) into account and evaluated the parameters together using multivariate regression analysis. We can subsequently derive testing results from this non-invasive blood pressure measurement method. The results show that in the normal blood pressure range, the error in systolic blood pressure (SBP) is 6.9mmHg ± 8.6mmHg. Although our results have not yet reached the AAMI standard, it has been verified that it is effective to integrate PTT and physiological parameters to estimate blood pressure.
| Original language | English |
|---|---|
| Title of host publication | 2016 International Automatic Control Conference, CACS 2016 |
| Publisher | Institute of Electrical and Electronics Engineers Inc. |
| Pages | 242-246 |
| Number of pages | 5 |
| ISBN (Electronic) | 9781509041084 |
| DOIs | |
| State | Published - 10 Jul 2017 |
| Event | 2016 International Automatic Control Conference, CACS 2016 - Taichung, Taiwan Duration: 9 Nov 2016 → 11 Nov 2016 |
Publication series
| Name | 2016 International Automatic Control Conference, CACS 2016 |
|---|
Conference
| Conference | 2016 International Automatic Control Conference, CACS 2016 |
|---|---|
| Country/Territory | Taiwan |
| City | Taichung |
| Period | 9/11/16 → 11/11/16 |
Bibliographical note
Publisher Copyright:© 2016 IEEE.
UN SDGs
This output contributes to the following UN Sustainable Development Goals (SDGs)
-
SDG 3 Good Health and Well-being
Keywords
- Blood Pressure
- Cuff-less
- ECG
- PPG
- PTT
- Wearable Device
Fingerprint
Dive into the research topics of 'Effects of pulse transit time and physiological differences on wearable device based blood pressure estimation'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver